Installing the propalms connection manager




















Follow these instructions to install the Connection Manager server and configure the server IO. Please follow the remaining instruction in this document to install Connection Manager Server. To communicate with instruments, you must install the Connection Manager server. Before installing the server, ensure that your PC workstation and your EDA software licensing meet the following requirements. The server must be installed on a Windows PC connected to the same network as the EDA software network server or local installation.

If you have Toshiba Bluetooth Stack installed on your system, you must uninstall it before installing Connection Manager server. Installing Toshiba Bluetooth Stack and Connection Manager server on the same system may cause undesirable effects including a system crash. Although the Connection Manager client requires a license, Connection Manager server does not require a license regardless of where it is installed.

The Connection Manager client is installed during the main software installation. Groups and Servers have a number of tabbed property pages with various customization options. Many of these pages are common to groups and servers. When the "Inherit from parent" check box is checked, the settings that follow are inherited from the parent container. Most server-related changes, e. This page only appears for the properties of a file.

It contains options for the file's group name, shows the full path to the file which can't be edited , and has a comment field. This page only appears for the properties of a group.

It contains options for the group name, parent nesting, and a comment. This page only appears for the properties of a server. It contains options for the server name, its display name, parent nesting, and a comment.

Use the PowerShell command:. The Logon Credentials property page contains options pertaining to remote login. The user name, password, and domain are set on this page. When logging in to a machine "domain" rather than a Windows domain, you can specify [server] or [display]. This former will be substituted with the server name, the latter with the display name, at logon time.

It is useful when you have a group of machines which require logging in as administrator. The Logon Settings entered in the properties pages are used by default for new connections. If you want to temporarily customize these settings for a new connection, connect using the Connect As menu item.

The Gateway name, authentication method, and local address bypass options are on this page. Users of operating systems starting from Vista SP1 and Longhorn server will have additional options regarding logon credentials:. Explicit entry of Gateway user name and password Ability to share the Gateway credentials with the remote server.

The Connection Settings tab includes settings to customize how a session is connected and what happens upon logon. You can specify whether the console session should be connected to as well as the remote desktop connection port. There are also settings that allow you to run a program upon connection. Enter the program name and, optionally, the working directory for that program.

Note that these only have an effect if you are connecting to the console session for the first time. That is, reconnecting to a session or connecting to a session other than the console session will not run the program. At least, this is how Terminal Services appears to work based on empirical observation. The size of the remote desktop is specified on this page. This is the logical desktop size, not the physical client view of it. For example, if the remote desktop size is x and client size is x , you would see a x view of the remote desktop with scroll bars.

If the client size were x , the entire remote desktop would be visible, offset by a gray border. Specifying "Same as client area" will make the remote desktop the same size as the RDCMan client panel, i. Specifying "Full screen" will make the remote desktop the same size as the screen that the server is viewed on.

Note that the remote desktop size is determined upon connecting to a server. Changing this setting for a connected server will have no effect. The maximum size of the remote desktop is determined by the version of the remote desktop activeX control.

Version 5 pre-Vista had a maximum of x ; Version 6 Vista has a maximum of x This limit is enforced at connection time, not during data entry. This is in case the same RDCMan file is shared by multiple computers. Various resources of the remote server may be delivered to the client.

The remote computer sound can be played locally, played remotely, or disabled entirely. Client drive, port, printer, smart card, and clipboard resources can be automatically shared to the remote machine.

You can specify whether authentication of the remote machine is required before a connection is established. The first option is: thumbnail scale. This specifies how many thumbnail units to allocate to the display of a given server. All servers default to a scale of 1. You can change this to increase the display of important servers. For example, a server could be scaled by 3 or 5 making the remote session quite usable in the thumbnail display while still permitting a view of many other servers.

Figure : Connecting to a wired network. Connecting to a Bluetooth device If a Bluetooth device is within range, Connection Manager will automatically connect. Figure : Connecting to a Bluetooth device. Setting Preferences Click Preferences to customize the application. The following settings are available:.

General - Allows you to determine when the application launches. Figure : Preferences - General screen. Notifications - Allows you to select the notifications to be displayed. Figure : Preferences - Notifications screen. Device Power - Allows you to select what devices to power on when launching.

Figure : Preferences - Device Power screen. Figure : Preferences - VPN screen. Figure : Mobile Broadband screen. It has been determined that this occurs when certain programs such as any year of Turbo Tax is also installed on the notebook. If you encounter this error, perform the following. Figure : SQL error during start up. This issue can be resolved by either of the following methods: Go to www. Remote Desktop Connection Manager Alternative.

Share on facebook. Share on twitter. Share on linkedin. Share on pinterest. Share on whatsapp. Downloads Download TSplus Software Try the software of your choice for 15 days and discover their incredible upsides! Read More ». Arabic English Turkish. Thank you for downloading, your download link is ready.



0コメント

  • 1000 / 1000